The Avante Waveline EZ patient monitor is the ideal option for healthcare professionals who demand accuracy, performance, and affordability. It boasts cutting-edge innovations and impeccable craftsmanship. It has a user-friendly touchscreen that makes it easier to quickly and accurately assess patient conditions, improving patient care. Use the Waveline EZ to track temperature, SpO2, NIBP, respiration, and ECG. For availability, get in touch with us. It's also available with EtCO2 monitoring and a printer.

Key Features:

  • Touch-screen provides immediate operation
  • Simultaneous multi-lead ECG monitoring
  • Masimo SET® Pulse Oximetry — ask your DRE representative for details
  • Advanced ST and arrhythmia detection
  • Graphical and tabular trending
  • Displays three waveforms
  • Battery backup
  • Audible and visual alarms
  • Quick BP readings recall

Documents and Resources:

**To download click below**

NIBP Connector Guide

SPO2 Probe Identifier

    Year Manufacturer's Warranty

    Avante Medical Surgical warranties its equipment to be free of defects in materials and workmanship under normal use and with appropriate maintenance. Length of warranty varies from product to product, so please confirm with your Avante Medical Surgical representative for specific warranty coverage. For plastics, rubber, or other expendable items, we warrant only that such parts will be free of defects in materials and workmanship at the time of purchase.

    PHYSICAL DIMENSIONS:

    • Size:6 lbs
    • Dimensions:10x8x4 (wxhxd)

    SAFETY APPROVAL & QUALITY SYSTEM:

    • Designed to meet IEC60601-1-1988, EN60601-1-1, EN60601-2
    • Class II Equipment, double insulated
    • Type BF applied parts
    • ISO9001 & EN46001 Certified

    POWER REQUIREMENTS:

    • Power Supply: AC 90-264V/47-63Hz
    • Input Power: ≤55VA
    • Fuses: Two fuse sockets in the rear panel indicated by “FUSE”, OI 5X20, 2A/250V
    • Battery: 12V/4.0AH sealed lead-acid
    • Charge time: ≥4 hours
    • Operating time: ≥2 hours (full recharge)
    • Battery Charging Method: Automatic charging after monitor is connected to AC power supply (with charge protection function)
    • Discharge Protection: When powered by battery, the monitor will be automatically turned off when battery power is almost used up

    ECG:

    • Patient Safety Standard: IEC60601-1-1988
    • CMRR ≥60dB (Common Mode Rejection Ratio)
    • Heart Rate Range: 20 ~ 254bpm 1bpm
    • Heart Rate Averaging: 8 second average
    • ST Segment Range: -0.8 ~ + 0.8mV
    • Interface: AAMI 6-pin
    • Lead Selection: I, II, III (3 lead mode)
    • I, II, III, aVR, aVL, aVF, V (5 lead mode) (ST and Arrhythmia analysis)
    • Lead Fault Alarm: Audible, Visual Input 5-lead ECG patient cable
    • QRS Indicator: Audible and Visual Alert
    • Waveform Storage: 6 minutes
    • Sweep Speed: 12.5/25/50 mm/sec
    • Gain Selection:4mV, 2mV, 1mV, 0.5mV, 0.25mV,Auto
    • Trends: 2 hours -> 4 hours -> 8 hours -> 24 hours -> 48 hours
    • Patient Isolation Breakdown: voltage 4000VAC 50Hz 60 seconds Leakage current <10μA
    • Frequency width Monitoring: mode 0.5 ~ 40Hz (+0.4dB,-3.0dB) Surgery mode 0.5 ~ 20Hz (+0.4dB, -3.0dB) not calibration significant
    • Patient Drive Current: <10μA
    • Enclosure Leakage Current: <0.1mA
    • Maximum T Wave Rejection Capability: 1.2mV
    • Heart Rate Alarm Response Time:< 7 seconds
    • Aspect Ratio: 0.24 ~ 0.6 sec/mV
    • Alarm Frequency Low alarm: 2-2.4kHz High alarm: 3-3.4kHz
    • Defibrillator Protected & ESIS Protected Tested with 5kV
    • Recovery Time Following Defibrillation: <5 seconds

    RESP:

    • Measurement Method: Thoracic Impedance
    • Respiration Rate Range: 0 ~ 1001rpm
    • Accuracy: 2 rpm

    MASIMO SET SPO2:

    • Measuring Range:
      • SpO2: 1?100 %
      • PR: 25?240 bpm
      • Perfusion: 0.02?20 %
    • SpO2 Accuracy (non-motion):
      • Adult Pediatric: 70?100 %: ±2 %, 0?69%: unspecified
      • Neonate: 70?100 %: ± 3 %,0?69 %: unspecified
    • SpO2 Accuracy (motion):
      • Adult Pediatric: 70?100 %: ±3 %, 0?69% : unspecified
      • Neonate: 70?100 %: ± 3 %, 0?69 % : unspecified
    • PR Accuracy (non-motion):
      • Adult Pediatric Neonate: 25?240 bpm: ±3 bpm
    • PR Accuracy (motion):
      • Adult Pediatric Neonate: 25?240 bpm: ±5 bpm
    • Low Perfusion Performance: >0.02 % Pulse Amplitude and % Transmission >5
      • SpO2: ±2 %
      • PR: ±3 bpm
    • Modes:
      • Averaging mode: 2,4,8,10,12,14 and 16 s
      • Sensitivity: Normal, APOD and Maximum

    NIBP:

    • Method Automatic oscillometric
    • Parameters Systolic, diastolic, mean arterial pressure, pulse
    • Scale mmHg or kPa
    • Operating Modes Manual, Automatic, Continuous
    • Repeat Cycles 1 ~ 10, 15, 30, 60, 90, 120 minutes
    • Determination Systolic, Adult/pediatric 40 ~ 250mmHg (5.3 ~ 33.3kPa) Systolic, Neonate 20 ~ 160mmHg (2.7 ~ 21.3kPa) Diastolic, Adult/pediatric 10 ~ 180mmHg (1.3 ~ 24.0kPa) Diastolic, Neonate 10 ~ 140mmHg (1.3 ~ 18.7kPa)
    • Cuff Pressure Range Adult/pediatric 0 ~ 300mmHg (0 ~ 40.0kPa) Neonate 0 ~ 140mmHg (0 ~ 18.7kPa)
    • Initial Cuff Inflation Adult/pediatric 17010mmHg (22.7 1.3kPa) Neonate 10010mmHg (16.0 1.3kPa)
    • Deflation Pressure 30mmHg(4.0kPa) higher than the last systolic pressure
    • Cuff Inflation Rate No greater than 50mmHg/sec
    • Measurement Time Typical 25 seconds, Maximum 40 seconds, Typical Stat 20 seconds
    • Pressure Display Accuracy 3mmHg
    • BP Pulse Rate Accuracy 2% @ 40 ~240bpm
    • Cuff Neonate, infant, pediatric, standard adult

    TEMP (DUAL CHANNEL):

    • Range 0 ~ 50C
    • Probe YSI 400 Skin surface or rectal /esophageal
    • Scale Celsius
    • Accuracy 0.1 C
    • Resolution 0.1 C

    CO2 (RESPIRONICS) (MAINSTREAM OR SIDESTREAM):

    • Type Side stream, mom-dispersive IR
    • CO2 Range 0-99mmHg
    • Scale mmHg/kPa
    • Accuracy +- 2mmHg (0-40mmHg) +- 5mmHg (41-76mmHg) +-10mmHg (77-99mmHg)
    • Calibration Automatic
    • Respiration Range 0-150rpm, +- 2rpm

    TFT COLOR DISPLAY:

    • Size 8 inches
    • Matrix 640 (H) x 480 (V) pixels
    • Recorder (Optional)
    • Type Built-in 2-channel thermal array recorder
    • Print mode Text or waveform
    • Waveforms Real time or alarm-triggered
    • Resolution 400dpi vertical, 800dpi horizontal
    • Annotations Time, date, vital sign readings

    Avante Ships from Kentucky via UPS Ground

    As soon as your order ships, we will send you a shipping notice with a tracking number. Use the map below to estimate the transit time needed for your item to be delivered from our warehouse to you:


      Fast Shipping

      We do our best to ship FAST and make it easy for you.  At the top of this page, we have noted how long it normally takes to process and ship your order with estimated delivery times.  We will send you an email confirmation with the tracking number as soon as your order ships.

      Please see our Shipping Policy for full details.

      Easy Returns

      Things don't always work out, we get it.  We'll do our very best to make your return simple and easy.  Please email us and we'll provide all the return instructions for your specific item and an RMA number (required).

      Please see our Return Policy for full details.

      Customer Reviews

      Be the first to write a review
      0%
      (0)
      0%
      (0)
      0%
      (0)
      0%
      (0)
      0%
      (0)